1.5 to 5 Tons

1.5 to 5 Tons
1½, 2, 2½, 3, 3½, 4, 5


 

 

 



The Trane XL 1600 air conditioning system, with its unique two-stage heating and cooling capability, minimizes the wide swings in temperature and humidity conditions associated with the "full blast" on-off control of traditional packaged equipment.

Features
 
  • Up to 16 SEER (Seasonal Energy Efficiency Rating), 80 AFUE at ARI-rated conditions
  • Reduced cooling airflow provides excellent humidity control at low load conditions
  • Variable outdoor air control provides proper ventilation at all operating conditions.
  • Dual compressors with variable air delivery reduce temperature swings and energy consumption at low load conditions.
  • One piece base pan reduces potential for water leaks.
  • Two-stages of gas heat with variable air delivery improves comfort at low load conditions.
  • Variable speed fan reduces sound levels at low load conditions.
  • High-gloss, porcelain-like powder coating and Lexan outdoor coil guards offer protection from life's little bumps and bruises.
  • Optional Acousti-Curb available in installations where sound issues are exceptionally important.


TCC-F Convertible
Tons Unit Model No. Power Supply
Volts/Phase/Hz
Performance SEER Cooling Capacity (Btuh) Dimensions
(in.)
H x W x L
Weights (lbs) Shipping MCA Max Fuse
Single Phase
TCC018F1 208/230/1/60 10.00 18,000 25 x 36 x 55 321 15.0 20
2 TCC024F1 208/230/1/60 10.00 23,400 25 x 36 x 55 321 17.7 25
TCC030F1 208/230/1/60 10.00 29,800 25 x 36 x 55 358 22.7 35
3 TCC036F1 208/230/1/60 10.00 35,200 25 x 36 x 55 380 24.8 45
TCC042F1 208/230/1/60 10.00 40,500 25 x 36 x 55 375 31.2 50
4 TCC048F1 208/230/1/60 10.00 48,000 Row 5 Col 6 536 37.5 55
5 TCC060F1 208/230/1/60 10.00 60,000 Row 6 Col 6 554 43.9 70
Three Phase
3 TCC036F3 208/230/3/60 10.00 35,400 29 x 36 x 55 380 19.9 30
TCC042F3 208/230/3/60 10.00 40,500 29 x 36 x 55 375 22.9 35
4 TCC048F3 208/230/3/60 10.00 48,000 33 x 45 x 64 536 27.0 40
5 TCC060F3 208/230/3/60 10.00 60,000 33 x 45 x 64 554 35.0 50
460 Volt
3 TCC036F4 460/3/60 10.00 35,400 29 x 36 x 55 380 10.5 15
4 TCC048F4 460/3/60 10.00 48,000 33 x 45 x 64 536 12.7 15
5 TCC060F4 460/3/60 10.00 60,000 33 x 45 x 64 554 16.3 25